Adhesion testing results on mini-module coupons (cell/encapsulant/glass laminates) that were aged under the following conditions.
- Hot-dry (90 Celsius, ~1% RH, no UV) for up to 10k hours
- Hot-humid (90 Celsius, ~60% RH, no UV) for up to 10k hours
- Warm-humid (60 Celsius, ~60% RH, no UV) for up to 10k hours
- IEC A3 (65 Celsius chamber setpoint, open-air, with UV source) for up to 10k hours
- IEC A3 for 2500 hours followed by Warm-humid for 2500 hours (1x sequence for 5k hours total, 2x sequence for 10k hours total)
- Warm-humid for 2500 hours followed by IEC A3 for 2500 hours (1x sequence for 5k hours total, 2x sequence for 10k hours total)
- IEC A3 for 2500 hours followed by warm-humid for 2500 hours followed by hot-dry for 2500 hours
Dataset Metadata